A FOB detector (FOB stands for foam on beer) is a small see-through bowl with a float in it, fitted in the beer line between the keg and the bar. Beer flowing through holds the float up. When the keg runs dry, gas and foam get into the bowl, the float drops and seals the line. The beer already in the line stays there, ready to pour, instead of being pushed out as froth. After you change the keg, you vent the bowl and reset the float, and you're back serving clear beer straight away.

That's it in a paragraph. Below is how to reset one properly, what position it goes in for line cleaning, what goes wrong with them, and an honest sum on whether they pay for themselves. Short answer on that last one: for a tenner to thirty quid a line, yes, quickly.

How a FOB detector works

Inside the bowl is a float. On a lot of UK models it's a ball. While beer is flowing, it holds the float up and away from the outlet. Micro Matic describes it as the beer flow forcing the float into the up position.

When the keg empties, the keg starts pushing gas and fob instead of beer. The bowl fills with foam, the float loses its lift, drops onto the outlet and seals it. Everything between the FOB and the tap is still full of good beer.

Without one, the gas carries on pushing up the line, the beer in the line gets broken up into froth, and when you connect the new keg you pull fob into the drip tray until the line runs clear again.

UK pub FOBs usually have:

  • a clear bowl, so you can see beer or foam inside
  • a vent button on top to let the gas and foam out after a keg change
  • a lever, knob or button to lift the float off its seat when you reset it, and to hold it open for line cleaning
  • push-fit fittings for the beer line

The Ecoflow detector sold by The One Stop Pub Shop, for example, lists a 3 and a half ounce chamber, an auto-close bleed valve and push-in fittings, and says every keg line should have one.

FOBs are for keg lines, the ones pushed by gas. A cask ale on a handpull is drawn up by the beer engine, not pushed by gas, so it doesn't use one.

How to reset a FOB detector after a keg change

Every make is a bit different, so the instructions on yours (or from your technical service team) always win. But they all follow the same four steps. These are based on Micro Matic's PRO-MAX operating instructions and the steps Cellar Dispense International sets out for standard FOBs.

  1. Change the keg. Take the coupler off the empty, put it on the new one and engage it. If you want the full routine, it's in my guide to changing a keg.
  2. Vent the bowl. Press and hold the vent button on top. Gas and foam come out, and the bowl fills up with beer from the new keg. Keep going until the bowl is full of clear beer. Micro Matic's sheet says to hold it for 10 seconds.
  3. Lift the float. Turn the lever, or push the button, to lift the float off its seat so beer can flow up the line again.
  4. Put it back to the serving position. Turn the lever back down, or let the button return. Then pull a pint at the bar. If it's frothy, go back and vent again.

Two things go wrong at this stage, and both cost money.

Leaving the vent open. On FOBs where the vent valve isn't spring-loaded, Cellar Dispense International warns that if it's left open, the contents of the keg will be lost. That's 88 pints on the cellar floor.

Not putting the lever back. If the float is left lifted, the FOB can't drop next time the keg runs out. Cellar Dispense International says the FOB will then fail and the fob comes out at the bar and splashes customers. That's also the moment you lose the line full of beer the FOB was there to save.

So a simple rule for whoever's changing kegs: after every change, look at the bowl. Full of clear beer, lever down, vent shut. Then walk away.

When must a FOB detector be reset?

Every time you change the keg on that line. It's also worth checking after line cleaning, because the float is held open for the clean and has to go back to the serving position afterwards. If the float drops on its own while the keg still has beer in it, see the faults section below.

What position should the FOB be in for line cleaning?

Open. The float needs to be lifted off its seat so the cleaning fluid can pass through the bowl and on up the line. Micro Matic says FOBs have a float-lifting device for exactly this, and that under no circumstances should they be bypassed during cleaning, because a FOB that never sees line cleaner will contaminate the beer.

There's one wrinkle. The same company's PRO-MAX instruction sheet says to bypass the FOB when cleaning with sponge pellets. So: clean through the FOB with the float held open, unless your FOB's own instructions say otherwise for the method you use. After the clean, put the lever back to the serving position, vent, and pull through until the beer is clear.

The FOB also needs stripping and cleaning by hand now and then. One US guide suggests every three months, using line cleaner. Check what your maker says, and keep it on the same calendar as your beer line cleaning.

What do FOB detectors cost in the UK?

Single keg FOBs are cheap. Prices I checked on 24 November 2026:

Retailer Model Price ex VAT Price inc VAT
Tec-Flo Ecoflo FOB Detector Mk2 £15.25 £18.30
The One Stop Pub Shop Ecoflow Fob Detector £20.95 not shown
Hallamshire FOB Detector (Ecoflo) £23.06 £27.67

Tec-Flo says its Mk2 is individually pressure tested and comes with a 3 year warranty. Fitting is a technician's job if you're not confident cutting into beer lines. And if your dispense kit belongs to your beer supplier, check with their technical service team before you change anything in the cellar.

Do FOB detectors pay for themselves? The sum

What a FOB saves depends on one thing: how much beer sits in the line between the keg and the tap. Without a FOB, that line fills with gas and froth when the keg runs out, and you pour roughly a line's worth away getting back to clear beer. Micro Matic works out its savings the same way, from the length and bore of the line.

How much beer is in your line

A line holds its cross-section times its length. Two common bores:

  • 9.5mm (3/8 inch) bore: about 71ml per metre
  • 6.35mm (1/4 inch) bore: about 32ml per metre

The bore is usually printed on the line. If you're not sure, ask your technician.

Line length, keg to tap 9.5mm bore 6.35mm bore
10 metres 0.71 litres, about 1.2 pints 0.32 litres, about 0.6 pints
20 metres 1.42 litres, about 2.5 pints 0.63 litres, about 1.1 pints
30 metres 2.13 litres, about 3.7 pints 0.95 litres, about 1.7 pints

(A UK pint is 568ml. For 9.5mm: a 0.475cm radius squared, times pi, times 100cm, is about 71ml a metre.)

Worked example: a busy lager line

Say your standard lager is 20 metres from the bar on a 9.5mm line, and you get through two 50 litre kegs a week on it.

  • Beer lost per keg change without a FOB: about 2.5 pints
  • 2 changes a week x 2.5 pints = 5 pints a week
  • At £1.88 a pint cost (a 50 litre keg of Carling at £165.72 ex VAT): 5 x £1.88 = £9.40 a week
  • Over a year: 52 x £9.40 = £488.80
  • A FOB at £15.25 to £23.06 ex VAT pays for itself in 2 to 3 weeks

Worked example: a quiet line

Now a slow guest keg, 10 metres away on a 6.35mm line, changed once a fortnight.

  • About 0.56 pints lost per change x 26 changes = 14.5 pints a year
  • 14.5 x £1.88 = £27.26 a year

Even there, a £15 to £23 FOB pays for itself inside a year. And that's before the time spent pulling fob, the glasses filled with froth, and the customer waiting at the bar while you do it.

These are estimates. How much you really lose depends on how quickly someone notices the keg has gone and how they clear the line. But they show why most keg lines have one.

Common FOB faults and what to do

Beer comes through as fob straight after a keg change. The FOB hasn't been vented fully, or the float hasn't been reset. Vent again until the bowl is full of clear beer, then reset. Also check the new keg has had time to settle and cool: a warm keg straight off the lorry will fob whatever the FOB does. The BII says new stock needs 48 hours to come down to cellar temperature (more in my beer cellar temperature guide).

The float sticks. The Enterprise technical guide, quoted in my why is my beer fobbing guide, says to release it with the button at the base and make sure it's left in the down position. A float that keeps sticking usually needs a strip and clean.

The FOB won't reset. Check the basics first. One US supplier's FAQ says to make sure the keg is properly seated and under gas pressure before blaming the FOB. A coupler that isn't fully engaged, or an empty gas bottle, looks exactly like a faulty FOB.

The float keeps dropping while the keg isn't empty. Something is getting gas into the bowl. Common culprits are a gas bottle running low, a keg that's over-gassed, or beer that's too warm and breaking out. If those check out, call your technician.

It's leaking. Don't bodge a beer line under pressure. Turn the gas off at the bottle for that line and ring your technical service team.

The FOB is dirty inside. If you can see deposits in the bowl, it isn't being cleaned through on line-cleaning day. See the line cleaning section above.

Where the FOB shows up in your stocktake

Lost beer from keg changes doesn't get rung through the till, so it lands in your draught variance. A line without a working FOB, or a team that's never been shown how to reset one, can quietly cost a few pints every keg. That's why I check FOBs when draught comes back short, along with the keg calibration and the line checks.

Counting often is what lets you spot it. StockTap lets you count part bottles by sliding to the level on a picture of the real bottle, or by weighing them for exact measures and value, so a weekly count is a quick job rather than a Sunday afternoon. There's a 14 day free trial, no card needed, then £39 a month, or you can stay on the Free plan.

Common questions

What does FOB stand for on a beer line?

Foam on beer. A FOB detector detects the foam that comes through when a keg runs dry and shuts the line.

When must a FOB detector be reset?

After every keg change on that line, and after line cleaning, when the float has been held open.

What position should the FOB detector be in during line cleaning?

Open, with the float lifted off its seat so cleaner runs through the bowl. Micro Matic says never bypass the FOB for cleaning, though its PRO-MAX sheet makes an exception for sponge pellets. Put it back to the serving position afterwards.

Do I need a FOB on every keg line?

Most suppliers say yes, and the sums above show why: even a slow line pays one back within a year. They aren't used on cask lines drawn by a handpull.

How much does a FOB detector cost?

Between £15.25 and £23.06 ex VAT for a single Ecoflo-type FOB at the UK retailers I checked on 24 November 2026.

Why is my FOB detector full of foam when the keg isn't empty?

Gas is getting into the bowl. Check the gas bottle, the coupler, and whether the beer is too warm. If it keeps happening, get your technician in.

Is there a newer, simpler type?

Cellar Dispense International announced a "One Button FOB" in March 2026 that needs one action to reset instead of three or four, with first production parts being trialled. Worth asking your supplier about if you're replacing old ones.

Sources

  • Micro Matic, Foam on Beer Detectors (how the float works, reset by venting, float-lifting device, never bypass for cleaning): micromatic.com
  • Micro Matic PRO-MAX-1 FOB operating instructions (vent 10 seconds, lever up and down, bypass for sponge pellets): PDF via webstaurantstore.com
  • BFBi member news, Cellar Dispense International One Button FOB (3 to 4 operations on standard FOBs, keg lost if valve left open, fob at the bar if not reset), 4 March 2026: bfbi.org.uk
  • Advanced Mixology, FOB detector guide (strip and clean every three months): advancedmixology.com
  • Wholesale Beer Parts, FOB detectors (check keg seated and pressurised if it won't reset): wholesalebeerparts.com
  • UK prices, checked 24 November 2026: Tec-Flo Ecoflo Mk2, The One Stop Pub Shop Ecoflow, Hallamshire Ecoflo
  • BII, Cellar cooling in a heatwave (48 hours for new stock): bii.org
  • Keg price per pint (Inn Express trade price, checked 15 Nov 2026): StockTap keg price guide